WHY WAIT FOR A VISIT
TO RESTART A DEVICE?
A streaming player that needs a restart should not become the evening’s main event. With ITAM’s BlueBOLT integration, you can restart connected equipment from the Utilities tab in ELAN. We design power protection, managed outlets and battery backup around the equipment you rely on.
Photo: Albert Stoynov / UnsplashPROTECT THE EQUIPMENT.
SIMPLIFY ITS CARE.
Keep the movie moving, the network connected and the rack easier to look after. Managed power puts device restarts in your ELAN Utilities controls and gives ITAM a way to check equipment remotely. Battery backup adds a different benefit: time to ride through an interruption or follow a planned shutdown.
PLAN THIS WITH ITAMTHE RIGHT POWER.
IN THE RIGHT PLACE.
Rack protection, vertical distribution, battery backup and compact device-level control. BlueBOLT management is included across this lineup. The MB1500 units ITAM supplies ship with a CV3 card.

M4315-PRO
Give your rack a better foundation.
Protect the equipment behind your music, movies and everyday control. Individually managed outlets let ITAM restart a device, while isolated filtration banks serve different parts of the system.
- 15-amp capacity for the residential rack
- 9 outlets: 8 individually controlled rear outlets and an always-on front outlet
- BlueBOLT remote power management included
M4315-PRO — A CLOSER LOOK
- Power capacity
- 15 A · 1,800 W at 120 V
- Outlets
- 9 total; 8 individually controlled rear outlets plus 1 always-on front outlet
- Filtration
- Three isolated LiFT filter banks plus one isolated high-current bank
- Protection
- Surge protection and automatic unsafe-voltage disconnect
- Control
- BlueBOLT remote management, power sequencing and 12 V triggering
- Installation
- One rack space; 19 inches wide with rack ears

VT1512-IP
Make room for the equipment.
Run managed power along the rack instead of using a horizontal equipment position. Twelve individually controlled outlets help organize a larger collection of connected devices and bring them back in the right sequence.
- 15-amp capacity with 12 individually controlled outlets
- Vertical rack mounting with included brackets
- BlueBOLT control and power sequencing included
VT1512-IP — A CLOSER LOOK
- Power capacity
- 15 A · 1,800 W at 120 V
- Outlets
- 12 individually controlled outlets; 3 spaced for power adapters and 6 turned 90 degrees
- Protection
- Surge protection, EMI/RFI filtration and over/under-voltage disconnect
- Control
- BlueBOLT cloud and local network monitoring/control; power sequencing
- Installation
- Vertical rack mounting; brackets included
- Power cord
- 10-foot cord with removable plug for length customization

MB1500
Give an interruption a plan.
An outage should have a planned response. Battery-backed power gives selected equipment time to keep operating through an interruption or shut down in an orderly way. ITAM sizes the load around what needs to stay available.
- 1,500 VA battery backup with true sine-wave output
- 8 battery-backed outlets with protection and filtration
- CV3 BlueBOLT card included with ITAM-supplied units
MB1500 — A CLOSER LOOK
- Battery capacity
- 1,500 VA; runtime follows the connected load and battery condition
- Output
- True sine wave with voltage regulation
- Outlets
- 8 outlets, all battery backed, surge protected and linearly filtered
- Protection
- Automatic voltage monitoring and Protect-or-Disconnect voltage protection
- Remote management
- CV3 BlueBOLT card included with ITAM-supplied units; RS-232 control also available
- Shutdown control
- Dual learning IR outputs and a USB interface

C3-IP
Restart the player. Keep your seat.
When a streaming player needs a restart, open Utilities in ELAN. The compact C3-IP lets you cycle its outlet from the interface you already use, with protected power tucked behind the TV or inside a media cabinet.
- Restart connected equipment from ELAN’s Utilities tab
- 3 individually controlled outlets; 12-amp capacity
- Slim enclosure with integrated mounting brackets
- BlueBOLT management and network auto-reboot included
C3-IP — A CLOSER LOOK
- Power capacity
- 12 A maximum at 120 V
- Outlets
- 3 individually controlled outlets
- Protection
- Surge protection, EMI/RFI filtration and over/under-voltage disconnect
- Control
- BlueBOLT monitoring, remote outlet control, scheduling and power sequencing
- Recovery
- Automatic reboot of network equipment when connectivity is lost
- Installation
- Slim wall-mount enclosure, including brackets; 7.35 × 5.5 × 1.58 inches

CAN YOU RESTART IT
WITHOUT CALLING FOR HELP?
- DEVICES POWERED THROUGH THE NETWORK
- ITAM’s two-way switch integration lets you restart individual PoE devices, including cameras and Wi-Fi access points, from the same Utilities tab.
When a streaming player, camera or Wi-Fi access point needs a restart, you shouldn’t have to hunt for a power cord. Open Utilities in ELAN and restart the device from the interface you already use.
- EQUIPMENT POWERED FROM AN OUTLET
- BlueBOLT power management lets you restart connected equipment from ELAN. The compact C3-IP puts that control close to a streaming player or television, tucked behind the screen or inside a media cabinet.
THE CONNECTIONS BEHIND THE CONTROLS
ITAM integrates Panamax BlueBOLT and two-way communication with Ubiquiti, NETGEAR, Luxul and Araknis PoE switches into ELAN. Outlet-powered equipment uses its managed power outlet; PoE devices use their switch-port power control. Device names and controls are arranged around the way you use your home.
LET’S MAKE THE SYSTEM EASIER TO LOOK AFTER.
We’ll review the equipment, the power arrangement and the support you need.
CONTACT ITAM
DESIGN · CONNECT · AUTOMATE